BELLOWS GLOBU VALVE
Upimaji:DIN 3352 Parf1 DIN 3230 Sehemu ya 3 DIN 2401 Ukadiriaji
Ubunifu:DIN 3356
Uso kwa uso:DIN 3202
Flanges:DIN 2501 DIN 2547 DIN 2526 FORME BWTO DIN 3239 DIN 3352 Parf1
Kuashiria : EN19 CE-PED
Vyeti: EN 10204-3.1B
Muundo wa Bidhaa
Sehemu Kuu na Nyenzo
SEHEMU YA JINA | NYENZO | ||
1 | Boby | 1.0619 | 1.4581 |
2 | Uso wa kiti | X20Cr13(1) wekeleo | 1.4581 (1) wekeleo |
3 | Uso wa kiti cha diski | X20Crl3(2) wekeleo | 1.4581 (2) wekeleo |
4 | Mvukuto | SS304/SS321/SS316L | SS321/SS316L |
5 | Gasket | Grafiti iliyoimarishwa ya SS(4) | S S. grophite iliyoimarishwa|4| |
6 | Karanga | C35 | A2-70 |
7 | Bolts | CK35 | A2-70 |
8 | Pocking | Pete za grafiti na pete za kuifuta (4) | Pete za grafiti na pete za kufuta |
9 | Tezi | 10460 | X5CrNiMol7-12-2 (2) |
10 | Bonati | 1.0619 | 1.4581 |
11 | Hakuna kuoza.Kifaa | X20Q13 | SS |
12 | Shina | X20Cr13(2) | X5CrNiVk)17-12-2 (2) |
13 | Nira Nut | GGG40(3) | GGG40.3 |
14 | Funga Nut | CS | CS |
15 | Hondwheel | Chuma | Steei |
16 | Paka Nipple mafuta | Cu-Aloi | S. S grafiti iliyoimarishwa |
UKUBWA KUU NA UZITO
FIG.P 061 BELLOWS SEAL STOP valves DIN PN16 – Uso kwa Uso F1 | ||||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 |
LRF | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 730 | 850 | 980 | 1100 |
D | 95 | 105 | 115 | 140 | 150 | 165 | 185 | 200 | 220 | 250 | 285 | 340 | 405 | 460 | 520 | 580 |
V | 120 | 140 | 140 | 140 | 160 | 160 | 180 | 200 | 250 | 250 | 350 | 450 | 500 | 500 | 600 | 600 |
H | 196 | 196 | 205 | 205 | 222 | 224 | 240 | 265 | 350 | 380 | 410 | 550 | 715 | 790 | 950 | 1030 |
KIHARUSI | 8 | 8 | 10 | 10 | 15 | 16 | 18 | 22 | 28 | 34 | 40 | 60 | 75 | 85 | 100 | 115 |
FIG.P 062 BELLOWS SEAL STOP valves DIN PN25 – Uso kwa Uso F1 | ||||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 |
LRF/BW | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 730 | 850 | 980 | noo |
D | 95 | 105 | 115 | 140 | 150 | 165 | 185 | 200 | 235 | 270 | 300 | 360 | 425 | 485 | 555 | 620 |
V | 140 | 140 | 160 | 160 | 180 | 180 | 200 | 250 | 300 | 350 | 400 | 500 | 500 | 500 | 600 | 600 |
H | 196 | 196 | 205 | 205 | 222 | 224 | 240 | 265 | 350 | 380 | 410 | 550 | 715 | 790 | 950 | 1030 |
KIHARUSI | 8 | 8 | 10 | 10 | 15 | 16 | 18 | 22 | 28 | 34 | 40 | 60 | 75 | 85 | 100 | 115 |
FIG.P.063 BELLOWS SEAL STOP valves DIN PN40 – Uso kwa Uso F1 | ||||||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 |
LRF/BW | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 730 | 850 | 980 | 1100 |
D | 95 | 105 | 115 | 140 | 150 | 165 | 185 | 200 | 235 | 270 | 300 | 375 | 450 | 515 | 580 | 660 |
V | 140 | 140 | 160 | 160 | 180 | 180 | 200 | 250 | 300 | 350 | 400 | 500 | 500 | 500 | 600 | 600 |
H | 196 | 196 | 205 | 205 | 222 | 224 | 240 | 265 | 350 | 380 | 410 | 550 | 715 | 790 | 950 | 1030 |
KIHARUSI | 8 | 8 | 10 | 10 | 15 | 16 | 18 | 22 | 28 | 34 | 40 | 60 | 75 | 85 | 100 | 115 |